By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.
Type:
Software - System Management
Version:
3.6.0(5 Oct 2020)
Operating System(s):
VMware vSphere 6.5
File name:
esxi6.5uX-mgmt-bundle-3.6.0-9.zip (15 MB)
The HPE ESXi Offline Bundle for VMware ESXi 6.5 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries.
Agentless Management Service
Added the option to enable/disable AHS Logical Disk Usage logging
To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:
Reboot Requirement: Reboot is required after installation for updates to take effect and hardware stability to be maintained.
Installation:
Installing Offline Bundles on an vSphere 6.5 Host Using vSphere CLI 6.5 esxcli Utility
You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes the procedure using offline bundles.
Prerequisites Before you can update or patch an vSphere 6.5 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.5 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the vSphere CLI 6.5, see the VMware vSphere Command-Line Interface Installation and Reference Guide.
Procedure
Power off any virtual machines that are running on the host and place the host into maintenance mode.
Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
Install the bundle on the ESXi host.
Install remotely from client, with offline bundle contents on a online depot: esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml>
Install remotely from client, with offline bundle on ESXi host: esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip>
Install from ESXi host, with offline bundle on ESXi host: esxcli software vib install -d <ESXi local path><bundle.zip>
After the bundle is installed, reboot the ESXi host for the updates to take effect.
(Optional) Verify that the vibs on the bundle are installed on your ESXi host. esxcli -s <server> -u root -p mypassword software vib list
(Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5. esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>
Installing Offline Bundles on an vSphere 6.5 Host Using VMware vCenter Update Manager
The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide.
End User License Agreements: HPE Software License Agreement v1 Eclipse License Libcurl End User License Agreement Net-SNMP License SNIA License zlib End User License Agreement Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Notes:
The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License. A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/
Supported Devices and Features:
VMware vSphere version support:
VMware vSphere 6.5 U2
VMware vSphere 6.5 U3
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Agentless Management Service
Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
Fix duplicate IP address reporting issue
Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
Disable Logical Disk Usage logging by default
Version:3.6.0 (5 Oct 2020)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Agentless Management Service
Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
Fix duplicate IP address reporting issue
Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
Disable Logical Disk Usage logging by default
Agentless Management Service
Added the option to enable/disable AHS Logical Disk Usage logging
Version:3.5.0 (17 Jan 2020)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
WBEM Providers
Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
Fix memory leak issues causing ESXi host to become unresponsive or crash
Agentless Management Service
Fix buffer overrun when acquiring vib summary from ESXi host database
Fix cpqSePciSlotBoardName for empty slots with no CPU
Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
Fix AMS hang when total IPv6 address string sizes exceed 256 bytes
Version:3.4.5 (16 Sep 2019)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Agentless Management Service
Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
Fixed issue with read spikes seen in Gen9 hosts with HPE 3PAR only every 5 minutes
Agentless Management Service
Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter
Version:3.4.0 (2 Apr 2019)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
WBEM Providers
Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider
Agentless Management Service
Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM
Agentless Management Service
Added support for cpqiscsi MIB
Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log
Version:3.3.6 (29 Nov 2018)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Agentless Management Service
Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.
Version:3.3.0 (27 Jun 2018)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
WBEM Providers
Fixed issue with Smart Array Provider reporting change of battery status frequently
Agentless Management Service
Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
Fixed memory leak partly caused by AMS running in the OS init resource group
Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display
WBEM Providers
Added support for Smart Array Controller model P408i-sb
Agentless Management Service
Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log
Version:3.2.0 (21 Mar 2018)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
WBEM Providers
Fixed to report HPE Smart array P816i-a SR Gen10 controller Information on vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019315en_us.
Fixed to report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5. For more information, see the customer advisory at http://h20566.www2.hpe.com/hpsc/doc/ public/display?docId=emr_na-a00016048en_us.
Fixed Memory leak issue in HPE Insight Management WBEM Provider on VMware vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.
Fixed to report HealthState property for HPVC_SAStorageVolume and HPVC_SAStorageExtent to match SSACLI status.
Fixed number of HPVC_SAStorageVolume instances to match with SSACLI.
Agentless Management Service
Fix continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system
Agentless Management Service
Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device
Added support for HPE Smart Array P824i-p MR controller
Added support for reporting multiple IPV6 addresses configured for Ethernet ports
Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers
Version:3.1.5 (9 Nov 2017)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
HPE Insight Management WBEM Providers:
HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5
This issue is observed on vSphere 6.5 when the server is configured with an HPE Dynamic Smart Array B140i Controller supported by the hpdsa driver and smart array controller supported by the nhpsa driver. In this configuration, the HPE Insight Management WBEM Provider do not report the HPE Dynamic Smart Array B140i Controller instances information it only reports the Smart Array Controller instances information.
HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5
This issue is observed on both vSphere 6.0 and 6.5 OS, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller.
HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated
When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts.
Fixed memory leak. For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.
HPE Agentless Management Service:
Fixed status for unconnected Fiber Channel ports that cause Fiber Channel Controller status to show as Degraded.
Fixed cpqIdeAtaDiskStatus which always shows SMART error and causing cpqIdeAtaDiskCondition as Degraded.
Added HPE Insight Management WBEM Provider support for new FCHBA.
Version:3.1.1 (28 Jul 2017)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Fixed Memory leak in HPE Insight Management WBEM Provider on VMware vSphere 6.5
Version:3.1.0 (12 Jul 2017)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
AMS fixes:
Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
Fixed AMS crash when multiple NICs of the same driver are installed
WBEM Provider features:
Gen10 and newer servers are Agentless, meaning the providers are limited to only the part of the Smart Array provider required to support Smart Array in VMware vCenter. Full providers continue to be supported on Gen9 and earlier servers.
Added support for smartpqi driver and Gen10 Smart Array controllers.
Added support to send Test Indication periodically to all the subscribers based on the time-interval value(days) configured from testevent utility.
Added Firmware update audit logging support to Smart Component Installer provider
AMS features:
Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port
Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor
The Agentless Management Service script to manually stop or restart AMS has changed from hp-ams.sh to ams.sh.
Version:2.6.2 (15 May 2017)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
There is an updated hpe-ilo driver included in this bundle. For more information, see the VMware Knowledge Base Article at http://kb.vmware.com/kb/2148123and the HPE Customer Advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=c05378386.
HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if an nhpsa driver supported HPE Smart Array Controller is also configured in the same server on vSphere 6.5 - This issue is observed on vSphere 6.5 when the server is configured with a combination of a HPE Dynamic Smart Array B140i Controller that supports hpdsa driver and a HPE Smart Array Controller that supports an nhpsa driver. The HPE Insight Management WBEM Providers does not report the HPE Dynamic Smart Array B140i Controller instances and only reports the HPE Smart Array Controller instances that supports the nhpsa driver.
Version:2.6.0 (18 Nov 2016)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Provider Features:
Added support for Native Interface in Ethernet Port Provider
Added support for Native interface in Smart Array Provider
AMS features:
Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives
Type:
Software - System Management
Version:
3.6.0(5 Oct 2020)
Operating System(s):
VMware vSphere 6.5
Description
The HPE ESXi Offline Bundle for VMware ESXi 6.5 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries.
Enhancements
Agentless Management Service
Added the option to enable/disable AHS Logical Disk Usage logging
Installation Instructions
To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:
Reboot Requirement: Reboot is required after installation for updates to take effect and hardware stability to be maintained.
Installation:
Installing Offline Bundles on an vSphere 6.5 Host Using vSphere CLI 6.5 esxcli Utility
You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes the procedure using offline bundles.
Prerequisites Before you can update or patch an vSphere 6.5 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.5 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the vSphere CLI 6.5, see the VMware vSphere Command-Line Interface Installation and Reference Guide.
Procedure
Power off any virtual machines that are running on the host and place the host into maintenance mode.
Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
Install the bundle on the ESXi host.
Install remotely from client, with offline bundle contents on a online depot: esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml>
Install remotely from client, with offline bundle on ESXi host: esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip>
Install from ESXi host, with offline bundle on ESXi host: esxcli software vib install -d <ESXi local path><bundle.zip>
After the bundle is installed, reboot the ESXi host for the updates to take effect.
(Optional) Verify that the vibs on the bundle are installed on your ESXi host. esxcli -s <server> -u root -p mypassword software vib list
(Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5. esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>
Installing Offline Bundles on an vSphere 6.5 Host Using VMware vCenter Update Manager
The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide.
Release Notes
End User License Agreements: HPE Software License Agreement v1 Eclipse License Libcurl End User License Agreement Net-SNMP License SNIA License zlib End User License Agreement Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Notes:
The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License. A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/
Supported Devices and Features:
VMware vSphere version support:
VMware vSphere 6.5 U2
VMware vSphere 6.5 U3
Fixes
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Agentless Management Service
Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
Fix duplicate IP address reporting issue
Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
Disable Logical Disk Usage logging by default
Revision History
Version:3.6.0 (5 Oct 2020)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Agentless Management Service
Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
Fix duplicate IP address reporting issue
Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
Disable Logical Disk Usage logging by default
Agentless Management Service
Added the option to enable/disable AHS Logical Disk Usage logging
Version:3.5.0 (17 Jan 2020)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
WBEM Providers
Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
Fix memory leak issues causing ESXi host to become unresponsive or crash
Agentless Management Service
Fix buffer overrun when acquiring vib summary from ESXi host database
Fix cpqSePciSlotBoardName for empty slots with no CPU
Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
Fix AMS hang when total IPv6 address string sizes exceed 256 bytes
Version:3.4.5 (16 Sep 2019)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Agentless Management Service
Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
Fixed issue with read spikes seen in Gen9 hosts with HPE 3PAR only every 5 minutes
Agentless Management Service
Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter
Version:3.4.0 (2 Apr 2019)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
WBEM Providers
Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider
Agentless Management Service
Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM
Agentless Management Service
Added support for cpqiscsi MIB
Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log
Version:3.3.6 (29 Nov 2018)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Agentless Management Service
Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.
Version:3.3.0 (27 Jun 2018)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
WBEM Providers
Fixed issue with Smart Array Provider reporting change of battery status frequently
Agentless Management Service
Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
Fixed memory leak partly caused by AMS running in the OS init resource group
Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display
WBEM Providers
Added support for Smart Array Controller model P408i-sb
Agentless Management Service
Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log
Version:3.2.0 (21 Mar 2018)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
WBEM Providers
Fixed to report HPE Smart array P816i-a SR Gen10 controller Information on vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019315en_us.
Fixed to report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5. For more information, see the customer advisory at http://h20566.www2.hpe.com/hpsc/doc/ public/display?docId=emr_na-a00016048en_us.
Fixed Memory leak issue in HPE Insight Management WBEM Provider on VMware vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.
Fixed to report HealthState property for HPVC_SAStorageVolume and HPVC_SAStorageExtent to match SSACLI status.
Fixed number of HPVC_SAStorageVolume instances to match with SSACLI.
Agentless Management Service
Fix continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system
Agentless Management Service
Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device
Added support for HPE Smart Array P824i-p MR controller
Added support for reporting multiple IPV6 addresses configured for Ethernet ports
Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers
Version:3.1.5 (9 Nov 2017)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
HPE Insight Management WBEM Providers:
HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5
This issue is observed on vSphere 6.5 when the server is configured with an HPE Dynamic Smart Array B140i Controller supported by the hpdsa driver and smart array controller supported by the nhpsa driver. In this configuration, the HPE Insight Management WBEM Provider do not report the HPE Dynamic Smart Array B140i Controller instances information it only reports the Smart Array Controller instances information.
HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5
This issue is observed on both vSphere 6.0 and 6.5 OS, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller.
HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated
When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts.
Fixed memory leak. For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.
HPE Agentless Management Service:
Fixed status for unconnected Fiber Channel ports that cause Fiber Channel Controller status to show as Degraded.
Fixed cpqIdeAtaDiskStatus which always shows SMART error and causing cpqIdeAtaDiskCondition as Degraded.
Added HPE Insight Management WBEM Provider support for new FCHBA.
Version:3.1.1 (28 Jul 2017)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Fixed Memory leak in HPE Insight Management WBEM Provider on VMware vSphere 6.5
Version:3.1.0 (12 Jul 2017)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
AMS fixes:
Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
Fixed AMS crash when multiple NICs of the same driver are installed
WBEM Provider features:
Gen10 and newer servers are Agentless, meaning the providers are limited to only the part of the Smart Array provider required to support Smart Array in VMware vCenter. Full providers continue to be supported on Gen9 and earlier servers.
Added support for smartpqi driver and Gen10 Smart Array controllers.
Added support to send Test Indication periodically to all the subscribers based on the time-interval value(days) configured from testevent utility.
Added Firmware update audit logging support to Smart Component Installer provider
AMS features:
Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port
Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor
The Agentless Management Service script to manually stop or restart AMS has changed from hp-ams.sh to ams.sh.
Version:2.6.2 (15 May 2017)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
There is an updated hpe-ilo driver included in this bundle. For more information, see the VMware Knowledge Base Article at http://kb.vmware.com/kb/2148123and the HPE Customer Advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=c05378386.
HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if an nhpsa driver supported HPE Smart Array Controller is also configured in the same server on vSphere 6.5 - This issue is observed on vSphere 6.5 when the server is configured with a combination of a HPE Dynamic Smart Array B140i Controller that supports hpdsa driver and a HPE Smart Array Controller that supports an nhpsa driver. The HPE Insight Management WBEM Providers does not report the HPE Dynamic Smart Array B140i Controller instances and only reports the HPE Smart Array Controller instances that supports the nhpsa driver.
Version:2.6.0 (18 Nov 2016)
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience.
Provider Features:
Added support for Native Interface in Ethernet Port Provider
Added support for Native interface in Smart Array Provider
AMS features:
Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives
Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.
With the enterprise storage scenario evolving rapidly, a dedicated storage solution is essential for organizations in order to increase security and reliability of data. According to statistics, the amount of data in an enterprise network doubles every year. With data growing at this rate, it is important for businesses and data centers to have a storage monitoring software in order to manage their data effectively.
Understand that the 3PAR SNMP Agent exposes a handful of basic system properties, such as system name, description, location and contact, and is limited to snmpget monitoring of CPU Stats (see the new 3PAR OS 3.3.1 cpuStatsMIB), while the ThreeParMIB.mib provides support for SNMP ‘alertNotify’ Traps (all alerts coming in under a common OID. Grafana.com provides a central repository where the community can come together to discover and share dashboards. Use these MIBs to manage and capture information from various Hewlett-Packard equipment, including Hewlett-Packard routers, switches, other devices and software agents. There are a total of 148 Hewlett-Packard MIB downloads in this section, containing over 33474 OIDS (Object Identifiers) in the proprietary Hewlett-Packard subtree.
Network Storage Monitoring Software
Dedicated storage solutions call for a dedicated storage management software. OpManager's integrated storage monitoring solution gives you the freedom of managing all your network storage devices from a single pane. With advanced performance monitoring and extensive reporting, OpManager packs a ton of features such as 'Disk Read/Write' stats, capacity utilization monitors and storage growth trend graphs to efficiently manage and monitor your storage devices round-the-clock. It enables you to monitor SAN components such as Fiber channel switches, Storage Arrays, and Tape Libraries which form the backbone of enterprise applications.
Benefits of monitoring storage devices with OpManager:
Increased visibility with unified view of your storage environment
Reduced downtime with timely detection of storage problems
Save administrative time with effective in-depth reporting and alarm escalations
Lower total cost of ownership with NO extra software purchases
Simplified storage management at an affordable price
Storage Performance Monitoring with OpManager
For in-depth network storage monitoring, OpManager's predefined storage monitor can be associated with storage devices to view the availability, for storage performance monitoring and to monitor various parameters of storage devices. OpManager also allows you to configure thresholds and depending of the criticality of the fault condition, each event and alarm is assigned a severity. OpManager simplifies storage device monitoring and is one among the leading storage monitoring tool available in the market.
Storage RAID Management with OpManager
OpManager utilizes SNMP / CLI / SMI-S/ vendor-specific APIs to discover and monitor the RAIDs in your network. For in-depth storage device monitoring, OpManager offers advanced asset management with comprehensive physical and logical asset details. You can view the health, availability and utilization of storage RAIDs and get alerted in real-time on hardware and software problems, drive failures and sensor faults. Reports based on performance and availability of storage RAIDs can be instantly generated over a period of time to aid with trend analysis. OpManager also helps you visualize your RAID storage network with topological maps of connections, link details table and color-coded icons to display the status with drill down option.
OpManager' />
Tape Library Monitoring & Management with OpManager
OpManager can automatically discover tape libraries in SAS / NAS networking vendor specific MIBs or APIs. Using OpManager, you can monitor the cleaning status, door status, operational status, etc. of tape libraries and addition, removal, mounting, unmounting, and other functions of tape drives. Reports based on availability trends, downtime history and MMTR reports can be generated for various time periods with OpManager.
Storage Capacity Forecasting with OpManager
OpManager offers advanced storage forecasting and capacity planning which helps you predict the storage requirements for your organization. You can predict the storage capacity by growth trend and utilization, get alerts when the specified capacity threshold is breached and schedule reports based on capacity trends. Take control of your storage devices with OpManager.
OpManager' />
Fabric Switch Management with OpManager
OpManager manages and monitors Fabric switches based on SNIA’s standard Fabric switch management MIBsand offers advanced insights by utilizing vendor specific MIBs and APIs. Asset and configuration details, capacity and performance of the Fabric switches and ports are readily available in OpManager and can also be generated as a report for detailed analysis. OpManager also offers advanced visualization capabilities like topological map of switches with their interconnections, link details and color-coded icons to quickly identify the status of a switch. OpManager’s real-time graphs and threshold based alarms help you to effortlessly monitor and manage the fabric switches in your environment.
IBM DS8000, IBM DS5000, IBM DS6000, IBM DS4000, BM N3300, N3600, N3700, N5200, N5300, N5500, N5600, N7700, N7900, IBM TS 3310, TS 3500, TS3100, TS3200, IBM ULT3582